Home › Guides › Power cuts & energy › Boiler not working after a power cut? What to check, safely
Guide · Power cuts

Boiler not working after a power cut? What to check, safely

Power is back but the boiler is not. The safe checks in order: wait, clock and timer, pressure gauge, one reset, a frozen pipe, and when it becomes a Gas Safe engineer's job.

In short

Smell gas or hear a carbon monoxide alarm? Leave, do not use switches or flames, open doors and windows if safe, turn the gas off at the meter if safe, and call 0800 111 999 (0800 002 001 in Northern Ireland). Otherwise: a gas boiler needs mains electricity for its pump, fan and controls, so it goes dark in a cut and usually comes back. When power returns, wait a few minutes, note any code, reset the clock, timer and thermostat, check the pressure gauge against your manual (often 1 to 1.5 bar when cold) and reset once, only as the manual describes. In freezing weather, thaw an outside condensate pipe with warm, never boiling, water. If it will not restart, the same code returns or the display stays blank with the house power on, only a Gas Safe registered engineer should open it, and it is usually a repair, not a new boiler.

By Tom Calder · Updated 12 October 2026 · Sourced to the HSE, National Gas, GOV.UK, Ofgem, Citizens Advice, the IET, network operators, Which? and boiler makers' fault-code pages

Share
Boiler not working after a power cut? What to check, safely

Why the boiler stops when the power does

Smell gas, or a carbon monoxide alarm sounding? Skip the rest of this page: leave the house, do not touch light switches or use a flame, open doors and windows on the way out if it is safe, turn the gas off at the meter if you can safely reach it, and call the National Gas Emergency Service on 0800 111 999 (0800 002 001 in Northern Ireland). The gas emergency steps are further down.

Otherwise, the explanation is simple. The gas kept flowing through the cut, but a modern gas boiler cannot use it without mains electricity: GOV.UK's WEEE guidance lists gas boilers among electrical equipment because they rely on electricity to work, and Northern Powergrid tells customers to check whether their gas heating will still function without it. The pump, fan, ignition and control board all run on the mains. Makers' manuals put the running draw of a typical combi at roughly 35 to 123 watts (Vaillant ecoTEC plus, Worcester Bosch Greenstar 4000 and Ideal Logic Max figures, set out in our backup power guide).

So a boiler that is dark during a power cut is not broken. The question is what happens when the power returns, and in most homes it is a few minutes of waiting, a clock to reset and, at worst, one reset done as the manual describes. First, though, confirm the cut is the cause: if the rest of the house has power and only the boiler is dark, check the boiler's own switch, the wall switch that feeds it (often a fused spur) and its breaker in the consumer unit. Citizens Advice says a breaker that keeps tripping should be left alone for a registered electrician.

While the power is off

Report the cut and ask how long it should last by calling 105, which is free in England, Scotland and Wales (in Northern Ireland, NIE Networks is on 03457 643 643). SSEN says heat can drop quickly in a power cut, so dress warmly, keep moving, and leave a light switched on so you know when the power is back. The UK Chief Medical Officers' advice for a national outage, published on GOV.UK in December 2025, is to stay inside, wear layers, gather in one room and close the curtains at dark; the NHS says to heat the rooms you use to at least 18°C if you can.

One shortcut is ruled out however cold it gets. The same GOV.UK advice says: 'Do not use camping stoves and barbecues indoors as there is a risk of carbon monoxide poisoning, which can kill', and do not run petrol or diesel generators or similar fuel-driven equipment indoors; a generator goes outdoors, at least 6 metres away, with its exhaust facing away from windows and doors. Northern Powergrid adds that outdoor heaters stay outdoors. Layers, blankets, a hot water bottle and a hot drink from a flask filled before the cut are the simple options; our guide to keeping warm without heating has the full list.

If anyone at home has reached State Pension age, is pregnant or has young children, is disabled, has a long-term health condition or relies on medical equipment that needs power, join the free Priority Services Register: Ofgem says it brings priority support in an emergency and, wherever possible, advance notice of planned power cuts.

When the power comes back: six checks, in order

1. Wait a few minutes. Many boilers run through a start-up sequence, and Vaillant says a restart can take several minutes or a second attempt. Look at the display before you press anything, and write down any code or flashing light it shows: it is the single most useful thing you can tell an engineer later.

2. Clock, timer and thermostat. Electricity North West says to reset the timer and thermostat as soon as the electricity comes back, along with any clocks that may have been affected. A programmer that has lost its time can run the heating at the wrong hours. Citizens Advice's checklist covers the rest: the heating is not set to 'off' or 'summer', the heating times are right, and the room thermostat is set above the room's temperature, or the boiler has no reason to fire. On a combi with no hot water, Citizens Advice suggests running a hot tap for a minute with the water set to at least 50°C.

3. Smart and wireless controls. A wireless thermostat or app-controlled system has its own recovery to do. Worcester Bosch says that in a power cut its EasyControl has no power and the heating appliance is switched off; when power returns it reboots, takes the time from the internet and restarts its programme. Because it gets the time online, your broadband router needs to be back up too, so give it a few minutes, and check a battery-powered thermostat still has fresh batteries.

4. The pressure gauge. Citizens Advice says that if the gauge reads below 1 bar you can repressurise following the manufacturer's guide: heating off and the boiler cool, aim for 1 to 1.5 bar, and close the filling-loop valves properly afterwards. Vaillant's, Glow-worm's and Ideal's fault-code pages all give 1 to 1.5 bar as the normal range, though Vaillant's ecoTEC plus manual accepts up to 2 bar when cold, so your own manual has the final word. If your manual does not show how to top up, or you cannot find the filling loop, leave it for an engineer.

5. One reset, the way the manual describes. Your manual says which faults you may reset and how; Citizens Advice notes that after thawing a frozen condensate pipe you might need to switch the boiler's power off and on again. Deal with the cause first, then reset once. If the same code returns or the boiler locks out again, stop: Vaillant says errors beyond the minor fixes should be looked at by a Gas Safe registered engineer, and some faults are not for the user at all (Baxi's 800 Combi manual marks those with a spanner symbol). Do not keep pressing reset.

6. In freezing weather, the condensate pipe. If the cut came with a cold snap, the plastic pipe that drains a condensing boiler may have frozen while the boiler stood cold. Worcester Bosch's manual says a frozen or blocked condensate pipe shuts the boiler down; Citizens Advice lists the signs as a fault code, gurgling or dripping. Thaw it only if it is outside, at ground level and easy to reach, using a hot water bottle, a microwaveable heat pack or a cloth soaked in warm water; Citizens Advice says not to use boiling water because it might melt the pipe. Our frozen condensate pipe guide shows the steps.

NewSee this for your own homeHome Alerts: your postcode's power cuts, warnings and floods, on one screen. Free for your own home. Opening in October; the first 100 on the list get in first.Join the list →

What the fault codes usually mean (and why none says 'power cut')

No maker we could read publishes a code that means 'there has been a power cut'. What people see after a cut are the ordinary pressure, ignition and lockout codes, which is why noting the exact code matters more than guessing from the brand. Below are codes you may meet, and what the maker says causes them.

Vaillant's fault-code table gives F.22 as low water pressure (below 1 to 1.5 bar; increase it slowly to that range), F.28 as no flame signal during ignition, caused by 'not enough gas reaching the boiler (for example, low gas pressure or insufficient credit on a pre-payment meter)', F.29 as a failed re-ignition after a flame loss (interrupted gas supply or low gas pressure), and F.54 as a gas supply fault seen with F.28 or F.29. Ideal's page gives a flashing F and 1 as low pressure (top up to 1 to 1.5 bar, reset; if that fails, contact Ideal) and a flashing L and 3 as no water flow.

Two practical points follow. First, an ignition code after a cut is a prompt to check the gas side, not the electrics: does the hob light, and on a prepayment meter is there credit? If the gas is off at the meter and you do not know why, leave it off and ask a Gas Safe registered engineer before it goes back on. Our winter boiler guide covers the meter and temporary credit. Second, a code that clears with one reset and does not return was most likely the restart itself; a code that comes straight back is the end of the resident's part of the job.

Surges and a damaged control board

Could the power coming back have damaged the boiler? It is possible, and there is no safe check a resident can make. The IET's consumer guidance on surge protection describes surges as transient overvoltages that can cause instant failure or damage that only shows over time, and it names boiler controls among the equipment worth weighing when deciding on protection. National Grid's distribution arm (NGED) warns that electrical surges during power cuts can damage digital devices and suggests turning sensitive electronics off or unplugging them. Neither source says how often a boiler's board is affected, and we will not guess.

Signs to describe to an engineer, not diagnose yourself: a display that stays blank with the house power, spur and breaker on; no attempt at ignition after one proper reset; repeat lockouts; any burning smell or sparking. With a burning smell, switch the boiler off at its switch and treat it as unsafe: the HSE says it is illegal to use a gas appliance you suspect is unsafe, and not to touch it until a Gas Safe registered engineer has checked it. A hard-wired boiler cannot be moved to a surge-protected extension lead; whole-house protection is an electrician's job, covered in our guide to power cuts and appliance damage.

On cost, two dated figures. Which?, which is independent, found in its June 2025 survey of 10,064 homeowners that the average paid for a one-off repair following a boiler service was £156. Selectra, a commercial comparison site that also refers readers to installers, lists a replacement printed circuit board at £250 to £380 fitted (May 2026 figures). Ring any home emergency or boiler cover insurer before booking: the Financial Ombudsman says most policies will not let you claim for a tradesperson you booked yourself. A boiler that fails after a power cut usually needs a repair or a reset, so get a repair quote before anyone talks about replacement.

When to call a Gas Safe engineer

The boundary is set by law. The Gas Safety (Installation and Use) Regulations 1998 say no one may work on a gas fitting unless competent to do so, and the HSE says anyone employed to work on gas appliances in a home must be a Gas Safe registered engineer competent for that work, shown on the back of their ID card. The Heating and Hotwater Industry Council says not to fit, fix or move a boiler yourself, and Worcester Bosch's manual says only a competent engineer can remove the casing. A resident's part happens with the casing on: switches, settings, the gauge, one reset, an external condensate pipe.

Call an engineer when: a code returns after one proper reset; an ignition or flame code persists once you have confirmed the gas is on at the meter and the hob lights; the boiler locks out repeatedly; the display stays blank with the house power, spur and breaker all on; the pressure keeps dropping (Citizens Advice says that if it changes over the next week, ask a Gas Safe engineer to look); or there is any burning smell or sparking. If a breaker keeps tripping, Citizens Advice says a registered electrician comes first. For oil, nidirect advises an OFTEC registered technician.

Check the engineer's ID card and licence number on the Gas Safe Register or by calling 0800 408 5500. If the boiler is still under the maker's guarantee, ring the maker first: Worcester Bosch's manual says it will not accept invoices for repairs by another firm. If you rent, the repair is normally your landlord's to arrange; report it in writing tonight and see the landlord sections of our winter boiler guide for how fast they must act. And make sure there is a working carbon monoxide alarm: the HSE strongly recommends one as a useful precaution, though not as a replacement for regular maintenance and safety checks.

If you smell gas or a carbon monoxide alarm sounds

Get everyone out. National Gas's steps: do not smoke or light matches, do not turn electrical switches on or off, open doors and windows if it is safe to, turn off the meter at the control handle unless the meter is in the cellar, and call the National Gas Emergency Service on 0800 111 999, free, day or night, making the call from outside. In Northern Ireland, call the NI Gas Emergency Service on 0800 002 001. For LPG, the Gas Safe Register says to call the number on the bulk tank or meter. Do not turn the supply back on until a Gas Safe registered engineer has checked it.

Carbon monoxide has no smell. If a CO alarm sounds, or people at home have headaches, dizziness or sickness that ease outdoors, National Gas says to stop using all appliances and switch them off, open doors and windows, get everyone out, call 0800 111 999 and not go back in until the emergency services advise you. The NHS says call 999 or go to A&E if someone exposed is finding it hard to breathe, is suddenly confused, has lost consciousness, feels weak or has chest or muscle pain, and not to drive there; call NHS 111 if you think you have symptoms.

Compensation for the cut, and backup power for next time

A long cut may be worth a payment, though it is for the disruption, not for the boiler. Ofgem's 2026/27 standards give £100 to a domestic customer if fewer than 5,000 properties were off for more than 12 hours (or 5,000 or more for more than 24 hours), with £45 for each further 12 hours, and separate storm rates; most payments are automatic. The amounts change each April, so use the calculator in our power cut compensation guide. If the boiler's board did fail, Citizens Advice says network operators do not have to pay for damaged devices but might make a goodwill payment: keep photos and the engineer's report.

If you want the boiler to keep running through the next cut, read our backup power for a gas boiler guide before buying anything. A combi draws little power, but it is hard-wired through a fused double-pole isolator, so a plug-in power station does not simply run it; a qualified electrician has to fit a suitable changeover arrangement, and the guide covers pure-sine-wave output, runtimes and thermostat receivers. Never wire a boiler to an extension lead from a power station or generator yourself, and never run a generator indoors. For heat without the boiler, see our electric heaters comparison and keeping warm in a power cut kit.

The honest bit
Almost everything on this page is waiting, checking settings, reading a gauge and one reset done the way your manual describes. That is deliberate: a boiler that goes dark in a power cut is usually just a boiler without electricity, and it usually comes back. If it does not, the same code returns or the display stays blank with the house power on, the resident's part is finished and it is a Gas Safe registered engineer's job, with the casing left on. A failed restart after a cut usually means a repair or a reset, and is not on its own a reason to buy a new boiler. And however cold the house gets, a barbecue, camping stove, patio heater or generator never comes indoors.

Common questions

Why won't my boiler restart after a power cut?

Usually because something lost its settings. Give it a few minutes (Vaillant says a restart can take several minutes or a second attempt), then reset the clock, timer and thermostat, as Electricity North West advises. Then look at the display: a pressure code means top up, only if your manual shows how; an ignition code means check the gas is on and the meter has credit. Reset once, as the manual describes. If the code returns, call a Gas Safe registered engineer.

Do I need to reset my boiler after a power cut?

Often not: many boilers restart on their own once power and the timer are back. If the display shows a fault, deal with the cause first (pressure, a frozen condensate pipe, gas at the meter), then reset once, only in the way your own manual shows. Some faults are not for the user to reset at all; Baxi's 800 Combi manual marks those with a spanner symbol. If the boiler locks out again, stop pressing reset and book a Gas Safe registered engineer.

Why is my boiler display blank after a power cut?

First confirm the house has power and the cut has really ended. Then check the boiler's own on/off switch, the wall switch that feeds it (often a fused spur) and its circuit breaker in the consumer unit. If a breaker goes straight back to off, Citizens Advice says leave it and ask a registered electrician. A blank display with power, spur and breaker all on is one for a Gas Safe registered engineer; it may be the control board, and there is no safe home check.

Can a power cut damage a boiler?

It can, and there is no safe home test. The IET says surges (transient overvoltages) can cause instant or delayed damage and names boiler controls among equipment worth protecting, and NGED warns that surges during power cuts can damage digital devices. A boiler that will not attempt ignition after one proper reset, or smells of burning, is for a Gas Safe registered engineer, switched off in the meantime. Ring any home emergency or boiler cover insurer before booking, and treat it as a repair question, not a replacement one.

Do I get compensation if my boiler broke in a power cut?

The payment is for the length of the cut, not for damage. Under Ofgem's 2026/27 standards, network operators pay £100 if fewer than 5,000 properties were off for more than 12 hours (24 hours for larger cuts), plus £45 for each further 12 hours, mostly automatically; figures change each April. For a damaged board, Citizens Advice says operators do not have to pay but might offer a goodwill payment: keep photos, receipts and the engineer's report, and check your home insurance or boiler cover.

Can I keep my boiler running from a power station or generator in the next cut?

Not by plugging it in. A combi draws only about 35 to 123 watts on makers' figures, but it is hard-wired through a fused isolator, so a qualified electrician has to fit a changeover arrangement first; our backup power guide explains the options. Never run a boiler from an extension lead you have rigged yourself, and never run a generator indoors: GOV.UK says it goes outdoors, at least 6 metres away, exhaust facing away from windows and doors, because of carbon monoxide.

Sources (37)
  1. HSE — Domestic gas: frequently asked questionsGas Safe registration, ID cards, unsafe appliances, CO alarms
  2. legislation.gov.uk — Gas Safety (Installation and Use) Regulations 1998, regulation 3 (competence)
  3. HHIC — Top gas safety tips, Gas Safety Week 2018only Gas Safe registered engineers work on boilers; mains voltage
  4. National Gas — Emergency contacts0800 111 999; what to do if you smell gas or suspect carbon monoxide
  5. Gas Safe Register — What to do in a gas emergencyLPG numbers; do not turn the supply back on until checked
  6. firmus energy — Gas emergency (NI Gas Emergency Service, 0800 002 001)
  7. NHS — Carbon monoxide poisoning
  8. NHS — Keep warm, keep well (heat rooms you use to at least 18°C)
  9. GOV.UK — Public health advice from the UK CMOs during a national power outage: keeping warm or coolDec 2025; no camping stoves, barbecues or generators indoors
  10. GOV.UK — Electrical and electronic equipment covered by the WEEE Regulations (gas boilers that rely on electricity)
  11. Northern Powergrid — What to do in a power cutcheck whether gas heating works without electricity; outdoor heaters stay outdoors
  12. Electricity North West — Tips to help you during a power cutreset timer and thermostat when power returns
  13. SSEN — What to do during a power cut (dress warmly, leave a light on)
  14. National Grid Electricity Distribution — What to do in a power cutsurges during power cuts can damage digital devices; unplug them
  15. Energy Networks Association — Power cut? Call 105
  16. NIE Networks — Power cuts in Northern Ireland (03457 643 643)
  17. IET — Consumer guidance: surge protective devicestransient overvoltages; instant or delayed damage; boiler controls among equipment to weigh
  18. Citizens Advice — Getting your broken boiler repaired or replacedswitches, settings, pressure, reset, condensate pipe
  19. Citizens Advice — Get compensation if you have a power cut (damaged devices and goodwill payments)
  20. Ofgem — Check if you can get a payment for a power cut (2026/27 amounts; call 105)
  21. Ofgem — Join your supplier's Priority Services Registerwho can join; priority support in an emergency; notice of planned cuts
  22. Financial Ombudsman Service — Home emergency insurancecontact the insurer before booking a tradesperson
  23. Vaillant — Boiler fault codes (F.22, F.28, F.29, F.54; 1 to 1.5 bar)
  24. Vaillant — How to reset a boilerdeal with the cause first; several minutes or a second attempt
  25. Vaillant — ecoTEC plus operating instructions (1 to 2 bar when cold)
  26. Vaillant — ecoTEC plus combi and system installation instructions (electrical power consumption)
  27. Worcester Bosch — Greenstar 4000 combi installation manualpower consumption; fused double-pole isolator
  28. Ideal — Logic Max Combi installation and servicingpower consumption; fused double-pole isolator
  29. Glow-worm — Boiler fault codes (pressure range 1 to 1.5 bar)
  30. Ideal Heating — Boiler fault codes (flashing F1 low pressure, L3 no water flow)
  31. Ideal Heating — Logic Combi troubleshooting guide (gas supply and prepayment checks)
  32. Worcester Bosch — Greenstar 4000 user instructions (2020): basic checks, condensate pipe, casing, guarantee
  33. Worcester Bosch — We've had a power cut, does that affect EasyControl?
  34. Baxi — 800 Combi user guide (spanner-symbol faults, reset, 1 to 1.5 bar when cold)
  35. nidirect — Domestic oil installation and boiler servicing (OFTEC registered technician)
  36. Which? — Getting the best boiler serviceJune 2025 survey of 10,064 homeowners: £156 average one-off repair after a service; page dated 8 Oct 2026
  37. Selectra (commercial comparison site that refers readers to installers; not a PreparedBritain partner) — Boiler repair costsPCB £250 to £380 fitted, May 2026 figures

PreparedBritain is independent and not affiliated with HM Government.

Free printable

The Power Cut Action Card

One page for the kitchen drawer: what to do first, what to have ready, how long food keeps, and how to stay warm without risking carbon monoxide. Free, no catch.

Download it straight away. We'll also send the occasional briefing when something genuinely matters — severe weather, live incidents, real price drops. Nothing else.

Latest from our live data

All stories →
Keeping warm in a power cut: kit →

Know someone who’d want this?

Follow PreparedBritain

A calm heads-up when a storm is named, scam warnings, and the money checkers worth knowing about, in your feed.